PRIMA LED CLASS II

One-row plastic industrial LED light fitting, with diffuser made of translucent polycarbonate with Class II insulation.

Product variants and technical data Clicking the 5-digit code displays other product information.
Code Type Ta Max.:
[°C]
Luminous flux of LED modules
[lm]
Luminous flux of light fitting:
[lm]
Power consumption:
[W]
System efficacy:
[lm/W]
Net weight:
[kg]
A
[mm]
D
[mm]
71200 PRIMA LED 1.2ft CLASS II PC 1300/840 45 1310 1170 8,2 143 1,3 662 350
71210 PRIMA LED 1.2ft CLASS II PC 1600/840 45 1560 1390 9,8 142 1,2 662 350
71220 PRIMA LED 1.2ft CLASS II PC 2200/840 40 2140 1900 13,2 144 1,3 662 350
71230 PRIMA LED 1.4ft CLASS II PC 2600/840 45 2600 2310 16,1 143 1,9 1272 700
71240 PRIMA LED 1.4ft CLASS II PC 3200/840 45 3100 2760 19,1 145 1,7 1272 700
71250 PRIMA LED 1.4ft CLASS II PC 4400/840 40 4300 3830 26 147 1,9 1272 700
71260 PRIMA LED 1.4ft CLASS II PC 6400/840 40 6120 5450 36,1 151 1,9 1272 700
71270 PRIMA LED 1.5ft CLASS II PC 3250/840 45 3240 2880 19,5 148 2,3 1572 940
71280 PRIMA LED 1.5ft CLASS II PC 4000/840 45 3850 3430 23,3 147 2,2 1572 940
71290 PRIMA LED 1.5ft CLASS II PC 5500/840 40 5340 4750 31,9 149 2,3 1572 940
71300 PRIMA LED 1.5ft CLASS II PC 8000/840 40 7780 6920 44,3 156 2,3 1572 940

Features

  • Constant luminous flux even in ambient temperature of -25 °C
  • Up to 45 % lower electricity consumption when compared to tubes
  • In DALI version: possibility of constant luminous flux for whole lifetime (CLO)
  • AWEX emergency light module generates a luminous flux of 440 lm
  • Available in ABS chemical resistant version
  • Optional throughwiring (up to 6 wires inside the light fitting)
  • Standard model - CRI > 80: 4000 K
  • At request CRI > 80: 3000 K, 5000 K, 6500 K, CRI > 90: 3000 K, 4000 K
  • The package includes stainless hooks and stainless brackets; if ordered without cables, packaging includes connector counterpart

Technical data

  • System efficacy: 156 lm/W
  • Degree of protection: IP66
  • Minimum ambient temperature: ta = -25 °C
  • Maximum ambient temperature: ta = 45 °C
  • Minimum ambient temperature: ta = 0 °C version with emergency back-up source
  • Maximum ambient temperature: ta = 25 °C version with emergency back-up source
  • Life time: 50000 hours / L90/B10
  • Unified Glare Ratio (UGR) from 18,8 to 22,2
  • Impact strength: IK10
  • Chromaticity tolerance (initial MacAdam): SDCM3
  • Certification CE, HACCP

Attachment method

  • Suitable for suspended mounting
  • Suitable for ceiling mounting
  • Suitable for wall mounting
  • Suitable for surface mounting

Materials / finishes

  • Body: grey PC (high mechanical resistance, UV stability, RAL 7035)
  • Diffuser: translucent PC (high mechanical resistance, UV stability)
  • Reflector: steel sheet, white (RAL 9003)
  • Clips: polyamide + 15 % fibreglass, stainless steel + polyamide
  • Sealing: polyurethane (PUR), foam-filled base groove
  • Connection: screwless two-pole terminal block, screwless two-pole terminal block, 2-wire connecting cabling for feed-through installation (1.5 mm2 cross-section, 2.5 mm2 available on demand), screwless four-pole terminal block, 4-wire connecting cabling for feed-through installation (1.5 mm2 cross-section, 2.5 mm2 available on demand), screwless four-pole terminal block, screwless six-pole terminal block, 6-wire connecting cabling for feed-through installation (1.5 mm2 cross-section, 2.5 mm2 available on demand), screwless six-pole terminal block
  • 2, 4 or 6-pole connectors, conductor cross-sectional area of 1.5 or 2.5 mm2

Electric equipment

  • It can be delivered in emergency version
  • It can be delivered in dimmable version

Download

Click the relevant product code in the table above to access the EULUMDAT (.ldt) files and the installation instructions for your luminaire.

BIM

Download the BIM objects.
More about BIM at bim.lighting.

Accessories to PRIMA LED CLASS II

Drawings and graphs of luminosity

Drawing

Nothing you say?

Check out instructions in which we explain what can be read from these graphs.

Light fitting is suitable for industrial, warehouse and agricultural buildings, sports premises, transport terminals, railway vehicle repair shops, platforms, traction substations, depots, parking lots and garages, workshops and laboratories without explosion hazard.

The light fitting resists dust, humidity and spouting water. The body and the diffuser made of PC material have high mechanical resistance against impact and deformation.

Emissions in the environment of use may reduce the usability of the plastics.